WhatsAppFast product support

TERMINAL BLOCK MEASUREMENT TOOL

Calculate pitch from the part in your hand.

Convert positions and a first-to-last contact-center measurement into nominal pitch, then compare the nearest current catalog references.

MEASURED CENTER SPANLFirst contact center to last
NUMBER OF INTERVALSN−1Positions minus one

PITCH = L / (N − 1) · NOMINAL CANDIDATE ONLY

MEASURE THE CONTACT SYSTEM—NOT THE HOUSING

A longer center span makes the pitch estimate easier to check.

Pitch is the nominal centerline spacing between equivalent adjacent contacts. Measuring across multiple intervals reduces the relative effect of caliper placement and reading error, but the result still needs a drawing.

01Use equivalent contact or pin centers.
02Measure first center to last center.
03Divide by positions minus one.
04Repeat, then verify drawing and sample.

PITCH MEASUREMENT CALCULATOR

Convert a first-to-last center span into nominal pitch.

Enter the number of positions and the measured distance from the center of the first contact to the center of the last contact. The tool divides the span by the number of intervals and ranks the nearest listed pitches.

INTERVALS3Positions minus one
CALCULATED PITCH5.08 mm15.24 mm divided by 3
NEAREST LISTED PITCH5.08 mmCandidate only—not proof of fit
  1. 01
    5.08 mmExpected span 15.24 mm · measured-span difference 0.00 mm
    14 listed models ↓
  2. 02
    5 mmExpected span 15.00 mm · measured-span difference 0.24 mm
    5 listed models ↓
  3. 03
    6.35 mmExpected span 19.05 mm · measured-span difference 3.81 mm
    1 listed models ↓

Formula: pitch = first-to-last contact-center span / (positions - 1). The nearest listed value is only a search candidate. Repeat the measurement, then verify pin layout, hole size, housing, orientation, mating geometry, electrical data, drawing and a physical sample.

MEASUREMENT WORKFLOW

Six checks before treating the result as a candidate.

  1. 01

    Count every physical position.

    A four-position terminal has three center-to-center intervals. Do not divide by the position count itself.

  2. 02

    Find the contact or pin centers.

    Use the centers of equivalent contacts in one row. Do not use the outside housing edges or screw-head diameter.

  3. 03

    Measure across several intervals.

    Measure from the first center to the last center. A longer span reduces the effect of reading and caliper-placement error.

  4. 04

    Divide by positions minus one.

    The result is a nominal pitch estimate. Compare it with documented centerline values and repeat the measurement.

  5. 05

    Verify the complete mechanical interface.

    Check hole and pin layout, rows, housing, wire entry, actuation, mating pair, keying, latch, flange and enclosure access.

  6. 06

    Close ratings and sample approval.

    Pitch cannot establish current, voltage, conductor range, material, certification or interchangeability. Confirm the exact drawing and sample.

CURRENT CATALOG PITCH DIRECTORY

12 nominal pitches across 53 current models.

The directory contains 55 pitch-to-model references because two shared Spring model pages cover separate 3.5 mm and 3.81 mm variants. Every link opens the current product evidence rather than claiming interchangeability.

2.5 MM / CURRENT CATALOG

3 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

2.54 MM / CURRENT CATALOG

2 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

3.5 MM / CURRENT CATALOG

7 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

3.81 MM / CURRENT CATALOG

9 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

5 MM / CURRENT CATALOG

5 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

5.08 MM / CURRENT CATALOG

14 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

6.35 MM / CURRENT CATALOG

1 listed model

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

7.5 MM / CURRENT CATALOG

1 listed model

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

7.62 MM / CURRENT CATALOG

5 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

8.25 MM / CURRENT CATALOG

2 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

9.5 MM / CURRENT CATALOG

4 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

10.16 MM / CURRENT CATALOG

2 listed models

Exact nominal-pitch references; final footprint and compatibility still require confirmation.

TECHNICAL BASIS

Centerline and pitch stay model-level product properties.

TE Connectivity lists PCB terminal block Centerline (Pitch) values alongside position count and product drawings. Phoenix Contact product data similarly separates pitch, positions, pin layout, hole diameter and connection method.

NEXT VERIFICATION STEP

Move the nominal result into a checkable RFQ.

Send the position count, measured center span, calculated pitch, photos, PCB footprint, connection type, mounting and wire-entry direction, conductor, ratings, quantity, target market and document requirements.

BUYER FAQ

Terminal block pitch measurement questions.

What is terminal block pitch?

Pitch is the nominal center-to-center distance between equivalent adjacent contacts or positions in the same row. Product manufacturers also describe it as centerline spacing.

Why do I divide by positions minus one?

Intervals sit between positions. A four-position block has three intervals, so the first-to-last center span covers three pitches.

Can I measure the total housing width instead?

No. Housing walls, end features, latches and flanges add dimensions that are not part of the contact-center pitch.

Does the nearest listed pitch prove the replacement will fit?

No. It is only a candidate for further checking. Verify the exact PCB pin layout, hole size, housing, orientation, mating geometry, ratings, drawing and sample.

Why are 5.0 mm and 5.08 mm separate candidates?

They are distinct nominal centerline values. The 0.08 mm difference accumulates across multiple intervals and can matter to a fixed PCB footprint.

Can pitch measurement reveal the electrical rating?

No. Current, voltage, conductor range, temperature, materials and required documents belong to the exact model and operating conditions.

HAVE A MEASUREMENT AND AN EXISTING PART?

Send the span, positions, photos and PCB evidence.

Email the measurement RFQ